DIG 110 MTP – Technical data
CAPACITY
| l/min |
| 0 |
270 |
540 |
810 |
1080 |
1350 |
1620 |
1890 |
2160 |
2430 |
2700 |
2970 |
3240 |
3510 |
3780 |
4100 |
| l/s |
| 0 |
4,5 |
9 |
13.5 |
18 |
22.5 |
27 |
31.5 |
36 |
40.5 |
45 |
49.5 |
54 |
58.5 |
63 |
68.3 |
| m3/h |
| 0 |
16.2 |
32.4 |
48.6 |
64.8 |
81 |
97.2 |
113.4 |
129.6 |
145.8 |
162 |
178.2 |
194.4 |
210.6 |
226.8 |
246 |
TOTAL MANOMETRIC HEAD
| m |
| 36.2 |
34.2 |
33 |
31.5 |
29 |
27.8 |
25.9 |
23 |
21.5 |
18.7 |
16,8 |
13.4 |
11.6 |
8.3 |
6.8 |
2,7 |
|
-H=UNI EN ISO 9906 < Sedimentation risk > Intermittent running
PUMP DATA
| m |
50 Hz |
60 Hz |
| ØImpeller (mm) |
168 |
150 |
| Impeller blade height (mm) |
62 |
62 |
| Ø Free passage (mm) |
10 |
10 |
| Weight (Kg) |
165 |
165 |
MOTOR DATA
| m |
50 Hz |
60 Hz |
| PN / Rated power (kW) |
11 |
11 |
| P1 / Network absorbed power (kW) |
13.5 |
13.5 |
| P2 / Power at the motor shaft (kW) |
10.8 |
10.8 |
| ƞ/ Hydraulic efficiency (%) |
72 |
72 |
| Phases |
3 |
3 |
| Voltage (V) |
400±10% |
400±10% |
| Frequency (Hz) |
50 |
60 |
| Revolutions per minute (RPM) |
2890 |
3470 |
| Poles |
2 |
2 |
| Rated current (A) |
24 |
24 |
| Capacitor (µF) |
- |
- |
| Power factor (COSɸ) |
0.89 |
0.89 |
Please note: Revision possible without prior notice.