DIG 85 MPT – Technical data
CAPACITY
| l/min |
| 0 |
225 |
450 |
675 |
900 |
1125 |
1350 |
1575 |
1800 |
2025 |
2250 |
2475 |
2700 |
2925 |
3150 |
3400 |
|
| l/s |
| 0 |
3.8 |
7.5 |
11.3 |
15 |
18.8 |
22.5 |
26.3 |
30 |
33.8 |
37.5 |
41.3 |
45 |
48.8 |
52.5 |
56.7 |
|
| m3/h |
| 0 |
13.3 |
27 |
40.3 |
54 |
67.5 |
81 |
94.5 |
108 |
121.5 |
135 |
148.5 |
162 |
175.5 |
189 |
204 |
|
TOTAL MANOMETRIC HEAD
| m |
| 27,5 |
26,7 |
26 |
24,7 |
23,1 |
22,5 |
20,4 |
18,9 |
17 |
15 |
13 |
11.5 |
9 |
7.5 |
5 |
2.5 |
|
-H=UNI EN ISO 9906 < Sedimentation risk > Intermittent running
PUMP DATA
| m |
50 Hz |
60 Hz |
| ØImpeller (mm) |
150 |
142 |
| Impeller blade height (mm) |
62 |
62 |
| Ø Free passage (mm) |
10 |
10 |
| Weight (Kg) |
150 |
150 |
MOTOR DATA
| m |
50 Hz |
60 Hz |
| PN / Rated power (kW) |
8.5 |
8.5 |
| P1 / Network absorbed power (kW) |
10.4 |
10.4 |
| P2 / Power at the motor shaft (kW) |
8.3 |
8.3 |
| ƞ/ Hydraulic efficiency (%) |
69 |
69 |
| Phases |
3 |
3 |
| Voltage (V) |
400±10% |
400±10% |
| Frequency (Hz) |
50 |
60 |
| Revolutions per minute (RPM) |
2890 |
3468 |
| Poles |
2 |
2 |
| Rated current (A) |
8.5 |
8.5 |
| Capacitor (µF) |
- |
- |
| Power factor (COSɸ) |
0.88 |
0.88 |
Please note: Revision possible without prior notice.