FUP 10 M S/A – Technical data
CAPACITY
| l/min |
| 0 |
50 |
75 |
100 |
125 |
150 |
175 |
200 |
225 |
250 |
275 |
300 |
325 |
350 |
375 |
400 |
|
| l/s |
| 0 |
0.8 |
1.3 |
1.6 |
2.1 |
2.5 |
2.9 |
3.3 |
3.8 |
4.2 |
4.6 |
5 |
5.4 |
5.8 |
6.3 |
6.6 |
|
| m3/h |
| 0 |
3 |
4.5 |
6 |
7.5 |
9 |
10.5 |
12 |
13.5 |
15 |
16.5 |
18 |
19.5 |
21 |
22.5 |
24 |
|
TOTAL MANOMETRIC HEAD
| m |
| 15 |
13.1 |
12.4 |
11.8 |
11.2 |
10.6 |
10 |
9.4 |
8.8 |
7.9 |
7.4 |
6.5 |
5.8 |
4.9 |
4 |
3.1 |
Q-H=UNI EN ISO 9906 < Sedimentation risk > Intermittent running
PUMP DATA
| |
50 Hz |
60 Hz |
| Ø Impeller (mm) |
116 |
103 |
| Impeller blade height (mm) |
17 |
17 |
| ø Free passage (mm) |
5 |
5 |
| Weight (Kg) |
11 |
11 |
MOTOR DATA
| |
50 Hz |
60 Hz |
| PN / Rated power (kW) |
1.1 |
1.1 |
| P1 / Network absorbed power (kW) |
1.4 |
1.4 |
| P2 / Power at the motor shaft (kW) |
0.95 |
0.95 |
| ƞ / Hydraulic efficiency (%) |
35 |
35 |
| Phases |
1 |
1 |
| Voltage (V) |
230±10% |
230±10% |
| Frequency (Hz) |
50 |
60 |
| Revolutions per minute (RPM) |
2720 |
3290 |
| Poles |
2 |
2 |
| Rated current (A) |
7 |
7 |
| Capacitor (µF) |
20 |
20 |
| Power factor (COSɸ) |
0.96 |
0.96 |
Please note: Revision possible without prior notice.