FUP BT 6 T – Technical data
CAPACITY
| l/min |
| 0 |
25 |
50 |
75 |
100 |
125 |
150 |
160 |
175 |
200 |
225 |
250 |
275 |
300 |
325 |
350 |
|
| l/s |
| 0 |
0.4 |
0.8 |
1.3 |
1.6 |
2.1 |
2.5 |
2.7 |
2.9 |
3.3 |
3.8 |
4.2 |
4.6 |
5 |
5.4 |
5.8 |
|
| m3/h |
| 0 |
1.5 |
3 |
4.5 |
6 |
7,5 |
9 |
10.5 |
11.2 |
12 |
13.5 |
15 |
16.5 |
18 |
19.5 |
21 |
|
TOTAL MANOMETRIC HEAD
| m |
| 11.9 |
11.5 |
11 |
10.4 |
9.8 |
9.2 |
8.5 |
7.9 |
7.5 |
7.2 |
6.5 |
5.8 |
5.1 |
4.5 |
3.9 |
3.5 |
|
Q-H=UNI EN ISO 9906 < Sedimentation risk > Intermittent running
PUMP DATA
| |
50 Hz |
60 Hz |
| Ø Impeller (mm) |
105 |
93 |
| Impeller blade height (mm) |
10 |
10 |
| ø Free passage (mm) |
5 |
5 |
| Weight (Kg) |
10 |
10 |
MOTOR DATA
| |
50 Hz |
60 Hz |
| PN / Rated power (kW) |
0.55 |
055 |
| P1 / Network absorbed power (kW) |
0.8 |
0.08 |
| P2 / Power at the motor shaft (kW) |
0.55 |
0.55 |
| ƞ / Hydraulic efficiency (%) |
45 |
45 |
| Phases |
3 |
3 |
| Voltage (V) |
400±10% |
230±10% |
| Frequency (Hz) |
50 |
60 |
| Revolutions per minute (RPM) |
2850 |
3420 |
| Poles |
2 |
2 |
| Rated current (A) |
1.5 |
1.5 |
| Capacitor (µF) |
- |
- |
| Power factor (COSɸ) |
0.75 |
0.75 |
Please note: Revision possible without prior notice.