JOLLY 904 M S/A – Technical data
CAPACITY
| l/min |
| 0 |
20 |
40 |
60 |
80 |
100 |
110 |
120 |
130 |
140 |
150 |
160 |
170 |
180 |
190 |
200 |
|
| l/s |
| 0 |
0.3 |
0.7 |
1 |
1.3 |
1.6 |
1.8 |
2 |
2.2 |
2.3 |
2.5 |
2.7 |
2.8 |
3 |
3.2 |
3.3 |
|
| m3/h |
| 0 |
1.2 |
2.4 |
3.6 |
4.8 |
6 |
6.6 |
7.2 |
7.8 |
8.4 |
9 |
9.,6 |
10.2 |
10.8 |
11.4 |
12 |
|
TOTAL MANOMETRIC HEAD
| m |
| 0 |
7.6 |
7.4 |
7 |
6.4 |
5.8 |
5 |
4.7 |
4.2 |
3.9 |
3.5 |
3 |
2.8 |
2.2 |
1.9 |
1.4 |
1 |
Q-H=UNI EN ISO 9906 < Sedimentation risk > Intermittent running
PUMP DATA
| m |
50 Hz |
60 Hz |
| ØImpeller (mm) |
110 |
100 |
| Impeller blade height (mm) |
17 |
10 |
| Ø Free passage (mm) |
30 |
30 |
| Weight (Kg) |
14 |
14 |
MOTOR DATA
| m |
50 Hz |
60 Hz |
| PN / Rated power (kW) |
0.4 |
0.4 |
| P1 / Network absorbed power (kW) |
0.6 |
0.6 |
| P2 / Power at the motor shaft (kW) |
0.38 |
0.38 |
| ƞ/ Hydraulic efficiency (%) |
28 |
28 |
| Phases |
1 |
1 |
| Voltage (V) |
230±10% |
230±10% |
| Frequency (Hz) |
50 |
50 |
| Revolutions per minute (RPM) |
2850 |
3420 |
| Poles |
2 |
2 |
| Rated current (A) |
3.6 |
3.6 |
| Capacitor (µF) |
12.5 |
12.5 |
| Power factor (COSɸ) |
0.96 |
0.96 |
Please note: Revision possible without prior notice.