RC 6300-4T Technical Data
RC AD 6300-4T Technical Data
CAPACITY
| l/min |
| 0 |
600 |
1200 |
1800 |
2400 |
3000 |
3600 |
4200 |
4800 |
5400 |
6000 |
6600 |
7200 |
7800 |
8400 |
8600 |
|
| l/s |
| 0 |
10 |
20 |
30 |
40 |
50 |
60 |
70 |
80 |
90 |
100 |
110 |
120 |
130 |
140 |
143.3 |
|
| m3/h |
| 0 |
36 |
72 |
108 |
144 |
180 |
216 |
252 |
288 |
324 |
360 |
396 |
432 |
468 |
504 |
516 |
|
TOTAL MANOMETRIC HEAD
| m |
| 34.3 |
30 |
26.2 |
23.9 |
21.5 |
19.5 |
18 |
16.2 |
15.2 |
14 |
12.3 |
11 |
9.5 |
8 |
6 |
4.8 |
|
-H=UNI EN ISO 9906 < Sedimentation risk > Intermittent running
PUMP DATA
| m |
50 Hz |
60 Hz |
| ØImpeller (mm) |
300 |
300 |
| Impeller blade height (mm) |
- |
- |
| Ø Free passage (mm) |
108 |
108 |
| Weight (Kg) |
340 |
340 |
MOTOR DATA
| m |
50 Hz |
60 Hz |
| PN / Rated power (kW) |
22 |
22 |
| P1 / Network absorbed power (kW) |
26 |
26 |
| P2 / Power at the motor shaft (kW) |
21 |
21 |
| ƞ/ Hydraulic efficiency (%) |
66 |
66 |
| Phases |
3 |
3 |
| Voltage (V) |
400±10% |
400±10% |
| Frequency (Hz) |
50 |
60 |
| Revolutions per minute (RPM) |
1450 |
1750 |
| Poles |
4 |
4 |
| Rated current (A) |
46 |
46 |
| Capacitor (µF) |
- |
- |
| Power factor (COSɸ) |
0.87 |
0.87 |
Please note: Revision possible without prior notice.