RC 8300-6T Technical Data
RC AD 8300-6T Technical Data
CAPACITY
| l/min |
| 0 |
850 |
1700 |
2550 |
3400 |
4250 |
5100 |
5950 |
6800 |
7650 |
8500 |
9350 |
10200 |
11050 |
11900 |
12750 |
|
| l/s |
| 0 |
14.2 |
28.3 |
42.5 |
56.7 |
70.8 |
85.0 |
99.2 |
113.3 |
127.5 |
141.7 |
155.8 |
170.0 |
184.2 |
198.3 |
212.5 |
|
| m3/h |
| 0 |
51 |
102 |
153 |
204 |
255 |
306 |
357 |
408 |
459 |
510 |
561 |
612 |
663 |
714 |
765 |
|
TOTAL MANOMETRIC HEAD
| m |
| 17 |
16.5 |
16.2 |
15.2 |
14.9 |
14.2 |
12.8 |
12 |
10.7 |
9.5 |
8.4 |
7.5 |
6.3 |
5.3 |
4 |
2.8 |
|
-H=UNI EN ISO 9906 < Sedimentation risk > Intermittent running
PUMP DATA
| m |
50 Hz |
60 Hz |
| ØImpeller (mm) |
366 |
- |
| Impeller blade height (mm) |
- |
- |
| Ø Free passage (mm) |
80 |
80 |
| Weight (Kg) |
505 |
505 |
MOTOR DATA
| m |
50 Hz |
60 Hz |
| PN / Rated power (kW) |
22 |
22 |
| P1 / Network absorbed power (kW) |
23 |
23 |
| P2 / Power at the motor shaft (kW) |
19.3 |
19.3 |
| ƞ/ Hydraulic efficiency (%) |
65 |
65 |
| Phases |
3 |
3 |
| Voltage (V) |
400±10% |
400±10% |
| Frequency (Hz) |
50 |
60 |
| Revolutions per minute (RPM) |
960 |
1160 |
| Poles |
6 |
6 |
| Rated current (A) |
45 |
45 |
| Capacitor (µF) |
- |
- |
| Power factor (COSɸ) |
0.83 |
0.83 |
Please note: Revision possible without prior notice.